HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gamillscheg, A
Right arrow Articles by Rigler, B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gamillscheg, A
Right arrow Articles by Rigler, B

Heart 1998;80:49-53 ( July )

Transcatheter coil occlusion of residual interatrial communications after Fontan procedure

A Gamillscheg,a A Beitzke,a J I Stein,a M Rupitz,a G Zobel,b B Riglerc

a Department of Paediatric Cardiology, Children's Hospital, University of Graz, Auenbruggerplatz 30, A-8036 Graz, Austria, b Department of Paediatrics, Children's Hospital, University of Graz, c Department of Cardiac Surgery, University of Graz

Correspondence to: Dr Gamillscheg.

Accepted for publication 23 February 1998

Objective---To assess the use of detachable coils as an alternative method to occlude interatrial communications after Fontan operations.
Design---Descriptive clinical study of selected patients after Fontan operation with interatrial communications inappropriate for transcatheter umbrella occlusion.
Setting---Tertiary paediatric cardiac referral centre.
Patients---Seven patients after Fontan operation with residual interatrial communications of various types producing a right to left shunt.
Interventions---Transcatheter placement of detachable coils with a diameter of 3 or 5 mm within the interatrial communication.
Results---A total of 14 coils were successfully placed within persistent patent fenestrations of the interatrial baffle, residual leaks at the suture line between the patch material and the right atrial wall, and unusual venous interatrial communications. The mean (SD) aortic oxygen saturation increased from 88 (1.1)% (range, 86-89%) to 92 (1.3)% (range, 89-93%; p < 0.001) and the mean (SD) right atrial pressure rose from 9.7 (2) mm Hg (range, 6-11) to 10.6 (2.4) mm Hg (range, 6-13; p < 0.05) after coil implantation. In five patients, complete obliteration of the interatrial shunt was shown by angiography after coil implantation. At a mean (SD) follow up of 10 (4) months (range, 3-15) a residual interatrial shunt was detected by Doppler colour echocardiography in only one patient, and oxygen saturations ranged from 90% to 95% (mean, 92%). There were no late coil embolisations, thromboembolic events, or haemolysis in any patient.
Conclusions---Detachable coils can be used successfully to occlude residual interatrial communications after the Fontan procedure. In selected cases, in whom intended transcatheter umbrella occlusion of residual interatrial leaks is not possible, the use of detachable coils might offer a safe alternative method to eliminate interatrial right to left shunting after the Fontan procedure.

Keywords: Fontan procedure;  residual interatrial communication;  coil occlusion


© 1998 by Heart



This article has been cited by other articles:


Home page
CirculationHome page
P. Khairy, N. Poirier, and L.-A. Mercier
Univentricular Heart
Circulation, February 13, 2007; 115(6): 800 - 812.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. J. Bradley, D. G. Human, J.A. G. Culham, W. J. Duncan, M. W. H. Patterson, J. G. LeBlanc, and S. S. Sett
Clipped tube fenestration after extracardiac Fontan allows for simple transcatheter coil occlusion
Ann. Thorac. Surg., December 1, 2003; 76(6): 1923 - 1928.
[Abstract] [Full Text] [PDF]